Copyright © 2026 Ningbo Honghui Xinzhi Technology Co., Ltd. All Rights Reserved XML
Automatic Metering Solenoid Valve Series:Most of this series of solenoid valves are precision-cast in full copper, featuring high strength, corrosion resistance and high temperature resistance, widely applicable to automatic cleaning equipment, water heaters, garden irrigation, infrared sensor sanitary ware and automatic metering water supply systems.
DCF-HT126N DC12V
Patent No.: ZL201120000330.2 Voltage: DC12V Starting Voltage: Rated Voltage ±10% Water Pressure Range: 0.02-0.8Mpa Service Life: Over 100,000 times Installation Spacing: 126*37mm G1/2 External Thread
Flowmeter Parameters: Working Voltage Range: DC4.5-24V Insulation Resistance: >100MΩ Accuracy: ±10% (at 1~25L/MIN) Flow Pulse Characteristic: F=7.8Q±10% Q=L/MIN Output Pulse High Level: >4.7V (Input Voltage DC5V) Output Pulse Low Level: <DC0.5V (Input Voltage DC5V)Customization: Custom design available for special requirements
DCF-HT127N DC12V
Patent No.: ZL201120000330.2 Voltage: DC12V Starting Voltage: Rated Voltage ±10% Water Pressure Range: 0.02-0.8Mpa Service Life: Over 100,000 times Installation Spacing: 127*37mm G1/2 External Thread
Flowmeter Parameters: Working Voltage Range: DC4.5-24V Insulation Resistance: >100MΩ Accuracy: ±10% (at 1~25L/MIN) Flow Pulse Characteristic: F=7.8Q±10% Q=L/MIN Output Pulse High Level: >4.7V (Input Voltage DC5V) Output Pulse Low Level: <DC0.5V (Input Voltage DC5V)Customization: Custom design available for special requirements
DCF-HT131 DC12V
Patent No.: ZL201120000330.2 Voltage: DC12V Starting Voltage: Rated Voltage ±10% Water Pressure Range: 0.02-0.8Mpa Service Life: Over 100,000 times Installation Spacing: 131*37mm G1/2 External Thread
Flowmeter Parameters: Working Voltage Range: DC4.5-24V Insulation Resistance: >100MΩ Accuracy: ±10% (at 1~25L/MIN) Flow Pulse Characteristic: F=7.8Q±10% Q=L/MIN Output Pulse High Level: >4.7V (Input Voltage DC5V) Output Pulse Low Level: <DC0.5V (Input Voltage DC5V)Customization: Custom design available for special requirements
DCF-HT135 DC12V
Patent No.: ZL201120000330.2 Voltage: DC12V Starting Voltage: Rated Voltage ±10% Water Pressure Range: 0.02-0.8Mpa Service Life: Over 100,000 times Installation Spacing: 135*37mm G1/2 External Thread
Flowmeter Parameters: Working Voltage Range: DC4.5-24V Insulation Resistance: >100MΩ Accuracy: ±10% (at 1~25L/MIN) Flow Pulse Characteristic: F=7.8Q±10% Q=L/MIN Output Pulse High Level: >4.7V (Input Voltage DC5V) Output Pulse Low Level: <DC0.5V (Input Voltage DC5V)Customization: Custom design available for special requirements